Russian version English version
Volume 10   Issue 2   Year 2015
References

  1. Mimics: Medical Image Segmentation for Engineering on Anatomy. http://biomedical.materialise.com/mimics (accessed 15 September 2015).
  2. Catia V5-6R2014. http://www.3ds.com/ru/produkty-i-uslugi/catia/produkty/catia-v5/ (accessed 20 September 2015).
  3. Ansys. http://www.ansys.com (accessed 20 September 2015).
  4. Microsoft Access. https://products.office.com/en-US/access (accessed 25 September 2015).
  5. Bonfield W., Li C.H. Anisotropy of nonelastic flow in bone. J. Appl. Phys. 1967;38:2450-2455. doi: 10.1063/1.1709926
  6. Evans F.G. In: Mechanical Properties of Bone. Charles C. Thomas, Springfield, IL; 1973. P. 282-310.
  7. Mather B.S. The symmetry of the mechanical properties of the human femur. J. Surg. Res. 1967;5:222-229. doi: 10.1016/0022-4804(67)90055-8
  8. Sedlin E.D. A rheological model for cortical bone. Acta Orthop. Scand. 1965;83:77.
  9. Yamada H. Strength of biological materials. Baltimore: Williams & Wilkins; 1970. 283 p.
  10. Knets I.V., Pfafrod G.O., Saulgozis Iu.Zh. Deformirovanie i razrushenie tverdykh biologicheskikh tkanei (Deformation and fracture of solid biological tissues). Riga; 1980. 319 p. (in Russ.).
  11. Bruiaka V.A., Fokin V.G., Soldusova E.A., Glazunova N.A.,  Adeianov I.E. Inzhenernyi analiz v Ansys Workbench (Engineering analysis in Ansys Workbench): textbook. Part I. Samara; 2010. 271 p. (in Russ.).
  12. Hansen E. Modelling heat transfer in a bone-cement-prosthesis system. Journal of Biomechanics. 2003;36:787-795. doi: 10.1016/S0021-9290(03)00012-5
  13. Naseer J. In: The Morning Echo: An Observation of Nature and Science. Bloomington: iUniverse; 2012. P. 443-460.
  14. Bergmann G., Graichen F., Rohlmann A., Verdonschot N., Lenthe G. Frictional heating of total hip implants. Part 2: finite element study. Journal of Biomechanics. 2001;34(4):429-435. doi: 10.1016/S0021-9290(00)00234-7
  15. Biyikli M., Modest M., Tarr R. Measurements of thermal properties for human femora. Journal of Biomedical Materials Research. 1986;20(9):1335-1345. doi: 10.1002/jbm.820200908
  16. Clattenburg R., Cohen J., Conner S., Cook N. Thermal properties of cancellous bone. Journal of Biomedical Materials Research. 1975;9(2):169-182. doi: 10.1002/jbm.820090206
  17. Mazzullo S., Paolini M., Verdi C. Numerical simulation of thermal bone necrosis during cementation of femoral prostheses. Journal of Mathematical Biology. 1991;29(5):475-494. doi: 10.1007/BF00160473
  18. Huiskes R. Some fundamental aspects of human joint replacement, analyses of stresses and heat conduction in bone-prosthesis structures. Acta Orthop. Scand. 1980;185:1-208. doi: 10.3109/ort.1980.51.suppl-185.01
  19. Zelenov E.S. Experimental investigation of the thermophysical properties of compact bone. Mechanics of Composite Materials. 1985:759-762.
  20. Stanczyk M., Telega J. Modelling of heat transfer in biomechanics - a review Part II. Orthopaedics. Acta of Bioengineering and Biomechanics. 2002;4(2):3-31.
  21. Kaorapapong K., Amornsamankul S., Tang I. Wiwatanapataphee B. Heat Transfer in Cemented Hip Replacement Process. International Journal of Mechanics. 2011;5(3):202-208.
  22. Dobelis M.A., Melnis A.É. Evaluation of the mechanical behavior of compact deproteinized and demineralized bone tissue under tension. Mechanics of Composite Materials. 1983;18(6):719-725. doi: 10.1007/BF00604156
Table of Contents Original Article
Anosov A.V., Kormilicyn O.P., Patrina T. A., Shemelinin D.A. Research of Mechanical Characteristics of Bone Tissues By Means Of the Developed Automated System of Medical Appointment. Ìàthematical biology and bioinformatics. 2015;10(2):548-561. doi: 10.17537/2015.10.548
(published in Russian)

Abstract (rus.)
Abstract (eng.)
Full text (rus., pdf)
References

 